UT SEP 1921/84 standard

This spec is applicable to forged and hot-rolled, raw or processed steel bars in alloyed or non-alloyed steels, in natural
state or treated condition. The inspection method for the search of internal defects can be freely chosen by the supplier (instrumentation, 1-4 MHz probes, coupling methods, etc.) as long as the test is carried out on the entire number of pieces. All defects (indications) bigger than the agreed-upon values must be described according to their position, size, extension and have to be reproduced in a drawing.

 

Acceptance limits

Table 1

Size Category Single defects, mm (1) Defects with extension, mm Max. extension, mm
A 14 10 80
B 10 7 60
C 7 5 40
D 5 3 30
E 3 2 30

(1) The distance between single defects must be min. 50 mm; where the distance is lower, defects must be
considered with their extension.

 

Number of defects on individual pieces

Table 2      

Frequency Category Number of defects Number of defects with extension
a 32 16
b 16 8
c 8 4
d 4 2
e 2 1